Please use this identifier to cite or link to this item: http://hdl.handle.net/2067/52242
Title: The global energy balance of the ASDEX Upgrade tokamak determined with the revised cooling water calorimetry
Authors: Redl, ANDREAS 
Hohmann, T
Eich, T
Vianello, N
Bernert, M
David, P
den Harder, N
Herrmann, A
Rohde, V
Weiland, M
the ASDEX Upgrade Team
the EUROfusion MST1 Team
Journal: PLASMA PHYSICS AND CONTROLLED FUSION 
Issue Date: 2023
Abstract: 
An extensive analysis of the global energy balance on the ASDEX Upgrade (AUG) tokamak has been performed. For such a purpose a complete revamping of the AUG cooling water calorimetry originally described in (Richter and Vernickel 1994 Rev. Sci. Instrum.65 5) has been done. The system, which has been largely improved, consists of 88 cooling units, which provides an almost perfect toroidal and poloidal coverage of the in-vessel components of the AUG tokamak. To measure the energy loss due to radiation, which is only partially captured by the cooling water calorimetry, a novel framework is introduced to calculate the losses utilizing bolometric data. The analysis of the global energy balance based on almost 600 discharges reveal the remarkable capability to account more than 95% of the total injected energy on average.
URI: http://hdl.handle.net/2067/52242
ISSN: 0741-3335
DOI: 10.1088/1361-6587/acfbb1
Rights: Attribution-NonCommercial-NoDerivatives 4.0 International
Appears in Collections:A1. Articolo in rivista

Files in This Item:
File Description SizeFormat
Redl_2023_Plasma_Phys._Control._Fusion_65_115003.pdf2.32 MBAdobe PDFView/Open
Show full item record

Page view(s)

33
checked on Jan 18, 2025

Download(s)

3
checked on Jan 18, 2025

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons