Utilizza questo identificativo per citare o creare un link a questo documento:
http://hdl.handle.net/2067/48407
Titolo: | Reliability of wearable sensors-based parameters for the assessment of knee stability | Autori: | Baldazzi, Andrea Molinaro, Luca Taborri, Juri Margheritini, Fabrizio Rossi, Stefano Bergamini, Elena |
Rivista: | PLOS ONE | Data pubblicazione: | 2022 | Abstract: | Anterior cruciate ligament (ACL) rupture represents one of the most recurrent knee injuries in soccer players. To allow a safe return to sport after ACL reconstruction, standardised and reliable procedures/criteria are needed. In this context, wearable sensors are gaining momentum as they allow obtaining objective information during sport-specific and in-the-field tasks. This paper aims at proposing a sensor-based protocol for the assessment of knee stability and at quantifying its reliability. Seventeen soccer players performed a single leg squat and a cross over hop test. Each participant was equipped with two magnetic-inertial measurement units located on the tibia and foot. Parameters related to the knee stability were obtained from linear acceleration and angular velocity signals. The intraclass correlation coefficient (ICC) and minimum detectable change (MDC) were calculated to evaluate each parameter reliability. The ICC ranged from 0.29 to 0.84 according to the considered parameter. Specifically, angular velocity-based parameters proved to be more reliable than acceleration-based counterparts, particularly in the cross over hop test (average ICC values of 0.46 and 0.63 for acceleration- and angular velocity-based parameters, respectively). An exception was represented, in the single leg squat, by parameters extracted from the acceleration trajectory on the tibial transverse plane (0.60≤ICC≤0.76), which can be considered as promising candidates for ACL injury risk assessment. Overall, greater ICC values were found for the dominant limb, with respect to the non-dominant one (average ICC: 0.64 and 0.53, respectively). Interestingly, this between-limb difference in variability was not always mirrored by LSI results. MDC values provide useful information in the perspective of applying the proposed protocol on athletes with ACL reconstruction. Thus, The outcome of this study sets the basis for the definition of reliable and objective criteria for return to sport clearance after ACL injury. |
URI: | http://hdl.handle.net/2067/48407 | ISSN: | 1932-6203 | DOI: | https://doi.org/10.1371/journal.pone.0274817 |
È visualizzato nelle collezioni: | A1. Articolo in rivista |
File in questo documento:
File | Descrizione | Dimensioni | Formato | Existing users please |
---|---|---|---|---|
journal.pone.0274817.pdf | 1.41 MB | Adobe PDF | Richiedi una copia |
Page view(s)
63
Last Week
0
0
Last month
2
2
controllato il 27-mar-2024
Download(s)
2
controllato il 27-mar-2024
Google ScholarTM
Check
Altmetric
Tutti i documenti nella community "Unitus Open Access" sono pubblicati ad accesso aperto.
Tutti i documenti nella community Prodotti della Ricerca" sono ad accesso riservato salvo diversa indicazione per alcuni documenti specifici