Utilizza questo identificativo per citare o creare un link a questo documento: http://hdl.handle.net/2067/43409
Titolo: Feasibility of ft-nir spectroscopy and vis/nir hyperspectral imaging for sorting unsound chestnuts
Autori: Bedini, Giacomo
Nallan Chakravartula, Swathi Sirisha
Bastianelli, Giorgia
Caccia, Romina
Contarini, Mario 
Morales-Rodríguez, Carmen
Rossini, Luca 
Speranza, Stefano 
Vannini, Andrea 
Moscetti, Roberto 
Massantini, Riccardo 
Rivista: ITALUS HORTUS 
Data pubblicazione: 2020
Abstract: 
Authors explored the potential use of Vis/NIR hyperspectral imaging (HSI) and Fourier-transform Near-Infrared (FT-NIR) spectroscopy to be used as in-line tools for the detection of unsound chestnut fruits (i.e. infected and/or infested) in comparison with the traditional sorting technique. For the intended purpose, a total of 720 raw fruits were collected from a local company. Chestnut fruits were preliminarily classified into sound (360 fruits) and unsound (360 fruits) batches using a proprietary floating system at the facility along with manual selection performed by expert workers. The two batches were stored at 4 ± 1 °C until use. Samples were left at ambient temperature for at least 12 h before measurements. Subsequently, fruits were subjected to non-destructive measurements (i.e. spectral analysis) immediately followed by destructive analyses (i.e. microbiological and entomological assays). Classification models were trained using the Partial Least Squares Discriminant Analysis (PLS-DA) by pairing the spectrum of each fruit with the categorical information obtained from its destructive assay (i.e., sound, Y = 0; unsound, Y = 1). Categorical data were also used to evaluate the classification performance of the traditional sorting method. The performance of each PLS-DA model was evaluated in terms of false positive error (FP), false negative error (FN) and total error (TE) rates. The best result (8% FP, 14% FN, 11% TE) was obtained using Savitzky-Golay first derivative with a 5-points window of smoothing on the dataset of raw reflectance spectra scanned from the hilum side of fruit using the Vis/NIR HSI setup. This model showed similarity in terms of False Negative error rate with the best one computed using data from the FT-NIR setup (i.e. 15% FN), which, however, had the lowest global performance (17% TE) due to the highest False Positive error rate (19%). Finally, considering that the total error rate committed by the traditional sorting system was about 14.5% with a tendency of misclassifying unsound fruits, the results indicate the feasibility of a rapid, in-line detection system based on spectroscopic measurements.
URI: http://hdl.handle.net/2067/43409
ISSN: 1127-3496
DOI: 10.26353/j.itahort/2020.1.0318
È visualizzato nelle collezioni:A1. Articolo in rivista

File in questo documento:
Visualizza tutti i metadati del documento

SCOPUSTM
Citations 10

3
Last Week
0
Last month
controllato il 29-nov-2021

Page view(s)

12
Last Week
0
Last month
1
controllato il 1-dic-2021

Google ScholarTM

Check

Altmetric


Tutti i documenti nella community "Unitus Open Access" sono pubblicati ad accesso aperto.
Tutti i documenti nella community Prodotti della Ricerca" sono ad accesso riservato salvo diversa indicazione per alcuni documenti specifici