Repository logo
Log In(current)
  1. Home
  2. Prodotti della ricerca
  3. D. Contributo in Atti di convegno
  4. D1. Contributo in Atti di convegno
  5. Porphyrin, graphene and polymers: smart combinations for selective nanofibrous chemosensors for gas and VOCs

Porphyrin, graphene and polymers: smart combinations for selective nanofibrous chemosensors for gas and VOCs

Author(s)
A. Macagnano
J. Avossa
E. Zampetti
R. Paolesse
Scarascia Mugnozza, Giuseppe  
more
Date Issued
2019
Type
conferenceObject
Start Page
21
End Page
21
Abstract
Polymer-carbon nanomaterials composites properties sound so attractive in various areas to have become a great challenge, too, in chemical sensors investigation. Here, a thin nanofibrous layer, composed of two insulating and eco-friendly thermoplastics (polystyrene-PS and polyhydroxibutyrate-PHB), a known percentage of nanofillers of mesoporous graphitized carbon (MGC) and a free-base tetraphenylporphyrin (H2TPP), has been deposited onto an interdigitated Micro-Electrode (IDE) by electrospinning technology and in a single step (Figure). The effects of the combination of a porphyrin with the composite system graphene-polymers appeared evident whenmnanofibrous layers, with- and without porphyrin, were compared about their morphology, electrical and sensing parameters. Both the resulting sensors wereconductive at room temperature and could work between 40 and 70-80 ◦C without an apparent degradation. Therefore porphyrindoped fibers appeared smoother and thinner (d: ≈175 nm) than porphyrin-free ones (d: ≈550 nm). The latter, indeed, looked extremely rough on the surface and decorated with brighter islands. However, both of them were more resistive at lower temperature, but became much more conductive when temperature rose to 60-70 °C. Porphyrin had a key role in adsorption and diffusion of chemicals, depending on its combination inside the composite fiber, since the response rates dramatically increased (toluene, acetic acid) with temperature. Conversely, the porphyrin-free sensor resulted highly sensitive and selective to acetic acid at 40◦C but the sensitivity fell down when the sensor operated at 80 ◦C. On the other hand, the same sensor increased its sensitivity only to NO2 when worked at 80°C, reporting a ~2 ppb limit of detection (LOD), thus confirming that temperature, as well as the free-base porphyrin, were two key players in driving the selectivity of the designed nanocomposite polymeric sensors.
Handle
http://hdl.handle.net/2067/47900
File(s)
Thumbnail Image
Name

Macagnano-EUPOC2019.pdf

Size

1.15 MB

Format

Adobe PDF

Checksum (MD5)

df890e19764e205bb834f061a4403283

Related items
Metrics
Conference(s)
European Polymer Conference 2019 (EUPOC2019) - ELECTROSPINNING AND RELATED TECHNIQUES: FROM DESIGN TO PRODUCTION OF ADVANCED POLYMER MATERIALS AND DEVICES