Repository logo
Log In(current)
  1. Home
  2. Prodotti della ricerca
  3. A. Contributo su rivista
  4. A1. Articolo in rivista
  5. Comparative Analysis of Markerless Motion Capture Systems for Measuring Human Kinematics

Comparative Analysis of Markerless Motion Capture Systems for Measuring Human Kinematics

Author(s)
Ceriola, Luca
Taborri, Juri  
Donati, Marco
Rossi, Stefano  
Patanè, Fabrizio
more
Date Issued
2024
Type
article
Volume
24
Issue
17
Start Page
28135
End Page
28144
DOI
10.1109/JSEN.2024.3431873
Journal
IEEE SENSORS JOURNAL  
Abstract
To date, there are several measurement methods for evaluating human kinematics based on inertial sensors or vision systems. However, a comprehensive comparison has not been undertaken to determine which of these systems offers the most appropriate accuracy for clinical or sports evaluations. This study conducted a comparative analysis of different motion measurement systems: optoelectronic system (OS), inertial measurement units (IMUs), and vision-based methods, including deep neural network (DNN) and non-DNN approaches. Ten healthy subjects were involved, performing walking (W.) and running (R.) tests at various speeds (3.5, 5.0, and 7.0 km/h). The measurement of human kinematics was conducted by taking video images via two RGB cameras, together with an IMU-based system and an OS as the gold standard. Comparative analysis was conducted on a set of measurement methods, including IMU, a method based on blob analysis (BA), and DNN algorithms: Alphapose (AP), TC former (TC), RTMPose (RTM), and MediaPipe (MP). Data analysis involved triangulation and measurement of lower limb joint angles. Results showed that vision systems do not allow ankle joint measurement, and IMUs outperformed other methods in terms of RMSE and absolute error of range of motion ( εROM) . RTM and MP exhibited results similar to IMUs, especially for the hip and knee joints, with the minimum absolute error reporting values of ( 3.1∘ ± 1.8∘) and ( 3.5∘ ± 1.9∘) for the hip joint and ( 4.0∘ ± 3.7∘) and ( 4.8∘ ± 4.3∘) for the knee joint, respectively.
Handle
http://hdl.handle.net/2067/51785
File(s)
Thumbnail Image
Name

Comparative_Analysis_of_Markerless_Motion_Capture_Systems_for_Measuring_Human_Kinematics.pdf

Size

6.96 MB

Format

Adobe PDF

Checksum (MD5)

2b72750f0e7a26acd70dc501c304234b

Metrics

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify