Analysis of the performances of a fuel cell CHP system under different energy demand and climate scenarios
Author(s)
Date Issued
November 18, 2019
Type
conference Object
Abstract
In this paper we assess the effective performance of a
cogeneration plant based on low temperature PEM fuel cells in
different energy scenarios. We vary the energy demand (office
apartment district, clinic, hotel, and supermarket) and the climatic
condition (Hot, Cooling Based, Moderate, Heating based, and
Cold). We also consider two control strategies: one that minimizes
the energy cost, and one that minimizes the primary energy
consumption. The plant performance is analyzed comparing the
energy cost and the primary energy consumption to the business
as usual scenario. The payback time is also evaluated to assess the
economic feasibility to the plant.