A Low-Cost Image Analysis System to Upgrade the Rudin Beer Foam Head Retention Meter

Author(s)
Cimini, Alessio  
Pallottino, Federico
Menesatti, Paolo
Moresi, Mauro  
Date Issued
2016
Type
article
Volume
9
Issue
9
Start Page
1587
End Page
1597
DOI
10.1007/s11947-016-1743-9
Journal
FOOD AND BIOPROCESS TECHNOLOGY  
Abstract
Beer foam is one of the first characteristics consumers visually perceive. Even if their opinions vary, generally, beer foam should be stable and long lasting. In this work, the conventional foam head retention method developed by Rudin (1957) was improved by resorting to three different automatic data acquisition systems. The first one made use of a mouse time tracking software offered at no cost. The second one was an Accurate Image Analysis system using a high-definition camera and a script written in MATLAB. Finally, the third one was an automatic low-cost image analysis (LCIA) system incorporating a Raspberry Pi single-board computer and a camera module (Raspberry Pi Foundation, UK). The latter was able not only to acquire the whole foam decay curve but also to fit the time course of the beer–foam interface position and extract the characteristic beer foam half-life (t½). All the data acquisition systems yielded t½ values practically coincident at the probability level of 0.05, this confirming their substantial equivalence. Once the lager beer had been laced with increasing doses of a foam agent (i.e., tetrahydro-iso-α-acid) to enhance its foam persistence, the resulting foam half-life, as estimated using the above Rudin-based methods, was highly correlated (r2 = 0.99) to the foam collapse time, as derived from the NIBEM Foam Stability Tester. Finally, thanks to the LCIA acquisition system developed here, the Rudin test might represent a fast, flexible, and cheaper alternative to the generally recommended but expensive NIBEM tester, as well as other commercial automated Rudin apparatuses.
Handle
http://hdl.handle.net/2067/47556
File(s)
Thumbnail Image
Name

ACCEPTED VERSION FABT-foam meter-April11th cim.pdf

Size

537.55 KB

Format

Adobe PDF

Checksum (MD5)

f52b0195b22f72240555e57140cfc31d

Metrics

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify